Product Description
R290 DC inverter heat pump is a new energy-saving solution which uses environmentally friendly R290 refrigerant and full DC inverter technology to heat, cool and to produce domestic hot water.
R290 refrigerant is a naturally occurring refrigerant, making it environmentally friendly, it has zero Ozone Depletion Potential (ODP=0), meaning it doesn’t contribute to the depletion of the ozone layer; And it has a low Global Warming Potential (GWP=3), meaning it doesn’t contribute significantly to global warming. It is the perfect solution for renovations, where a high water outlet temperature is required.
Guangteng heat pump with R290 refrigerant is the real full inverter heat pump by DC inverter compressor, DC inverter control system and DC inverter fan motor. Inverter technology makes it possible to automatically adapt the compressor and fan rotation speed to the house heating needs and to weather conditions.
Guangteng R290 DC inverter heat pumps are tested by TUV, achieving the ERP A+++ energy class, the highest energy efficiency.
With smart WiFi APP control, you can check or control your heat pump anytime, anywhere easily.
Touch Display
If you want to know more information about R290 DC inverter heat pump, please contact us. We will provide professional answers.
Model number | GT-SKR020KBDC-M290 | GT-SKR030KBDC-M290 | GT-SKR040KBDC-M290 | GT-SKR040KBDC-M290T | GT-SKR050KBDC-M290T | |
Heating at A7/W35 | ||||||
Heating capacity (min~max) | KW | 6.40 (2.83~8.00) | 8.30 (3.65~10.38) | 11.60 (5.10~14.50) | 12.00 (5.28~15.00) | 16.30 (8.80~21.20) |
Power input (min~max) | KW | 1.47 (0.65~1.84) | 1.93 (0.85~2.42) | 2.75 (1.21~3.44) | 2.90 (1.28~3.63) | 3.69 (1.99-4.80) |
COP | W/W | 4.34 (3.03~5.21) | 4.30 (3.01~5.16) | 4.22 (3.03~5.10) | 4.15 (3.0~5.0) | 4.42 (3.1~5.3) |
Heating at A2/W35 | ||||||
Heating capacity (min~max) | KW | 5.80 (2.55~7.25) | 7.11 (3.13~8.89) | 10.43 (4.59~13.04) | 10.30 (4.53~12.88) | 14.31 (6.86~18.60) |
Power input (min~max) | KW | 1.60 (0.71~2.00) | 2.06 (0.91~258) | 2.76 (1.22~3.45) | 2.85 (1.25~3.56) | 3.67 (1.98~4.84) |
COP | W/W | 3.60 (2.52-4.32) | 3.45 (2.48~4.30) | 3.78 (2.65~4.54) | 3.61 (2.53~4.40) | 3.90 (2.73~4.68) |
Heating at A7/W55 | ||||||
Heating capacity (min~max) | KW | 5.75 (2.53~7.19) | 7.70 (3.40~9.63) | 11.08 (4.88~13.85) | 11.43 (5.03~14.29) | 14.71 (7.94~19.13) |
Power input (min~max) | KW | 2.03 (0.89~2.54) | 2.70 (1.19~3.38) | 3.82 (1.68~4.78) | 4.07 (1.79~5.09) | 5.02 (2.71~6.53) |
COP | W/W | 2.83 (2.3-3.8) | 2.85 (2.00-3.42) | 2.90 (2.03-3.48) | 2.81 (2.02-3.41) | 2.93 (2.05-3.52) |
Heating at A2/W55 | ||||||
Heating capacity (min~max) | KW | 5.14 (2.27~6.43) | 6.72 (2.96~8.40) | 9.61 (4.23~12.00) | 9.70 (4.59~12.63) | 13.81 (7.45~17.95) |
Power input (min~max) | KW | 2.06 (0.91~2.58) | 2.71 (1.20~3.39) | 3.74 (1.65~4.68) | 3.99 (1.76~4.84) | 4.93 (2.66~6.41) |
COP | W/W | 2.45 (2.0-3.45) | 2.48 (2.0-3.6) | 2.57 (2.2-3.7) | 2.43 (2.0-3.6) | 2.80 (2.2-3.9) |
Cooling at A35/W7 | ||||||
Cooling capacity (min~max) | KW | 3.70 (2.22~5.92) | 6.20 (3.40~8.10) | 9.30 (5.15~12.09) | 9.50 (5.22~12.35) | 13.30 (7.10~17.3) |
power input (min~max) | KW | 1.32 (0.79~2.11) | 2.20 (1.21~2.86) | 3.25 (1.76~4.16) | 3.28 (1.79~4.20) | 4.60 (2.53~5.98) |
EER | W/W | 2.80 (2.02-3.36) | 2.80 (2.00-3.42) | 2.85 (2.05-3.42) | 2.80 (2.00-3.50) | 2.90 (2.10-3.48) |
SCOP | ||||||
SCOP (TWW for 35°C class) | N/A | 4.47 | 4.49 | 4.59 | 4.63 | 4.51 |
Energy lable(TWW at 35°C) | N/A | A+++ | A+++ | A+++ | A+++ | A+++ |
SCOP (TWW for 55°C class) | N/A | 3.59 | 3.58 | 3.67 | 3.60 | 3.62 |
Energy lable(TWW at 55°C) | N/A | A++ | A++ | A++ | A++ | A++ |
Power supply | V/Ph | 220~240/1/50 | 220~240/1/50 | 220~240/1/50 | 380~415/3N/50 | 380~415/3N/50 |
Compressor | N/A | DC Inverter | DC Inverter | DC Inverter | DC Inverter | DC Inverter |
Fan motor | N/A | DC | DC | DC | DC | DC |
Fan motor qty | pc | 1 | 1 | 2 | 2 | 2 |
Water circulation pump | N/A | Inverter | Inverter | Inverter | Inverter | Inverter |
Refrigerant | N/A | R290 / 700g | R290 / 1100g | R290 / 1200g | R290 / 1200g | R290 / 1600g |
CO2 equivalent | T | 0.0021 | 0.0033 | 0.0036 | 0.0036 | 0.0048 |
Refrigerant regulation | N/A | Electronic expansion valve | ||||
Heat exchanger type | N/A | Brazed plate heat exchanger | ||||
Water connection | Inch | 1 | 1 | 1 | 1 | 1 |
Norminal water flow | m3/h | 1.4 | 1.8 | 2.7 | 2.7 | 3.6 |
Operating outdoor temp | ℃ | -25~43 | -25~43 | -25~43 | -25~43 | -25~43 |
Max heating water temp | ℃ | 75 | 75 | 75 | 75 | 75 |
Min cooling water temp | ℃ | 10 | 10 | 10 | 10 | 10 |
Sound level | dB(A) | 60 | 63 | 67 | 67 | 73 |
Degree of protection | N/A | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 |
Net weight | kg | 80 | 85 | 99 | 99 | 135 |
Dimension | mm | 1100*460*795 | 1100*460*795 | 1115*470*1020 | 1115*470*1020 | 1165*470*1280 |
1. A7/W35: outdoor air temperature 7℃ DB/6℃ WB, water inlet/outlet temperature 30℃/35℃
2. A2/W35: outdoor air temperature 2℃ DB/1℃ WB, water inlet/outlet temperature 30℃/35℃
3. A7/W55: outdoor air temperature 7℃ DB/6℃ WB, water inlet/outlet temperature 47℃/55℃
4. A2/W55: outdoor air temperature 2℃ DB/1℃ WB, water inlet/outlet temperature 47℃/55℃
5. A35/W7: outdoor air temperature 35℃ , water inlet/outlet temperature 12℃/7℃
Copyright © Foshan Guangteng New Energy Co., Ltd. All Rights Reserved. Powered by: REANOD Sitemap